Skip to content
GT New HorizonsGTNH 2.9.0 · Community server

GT New Horizons · Ludicrous Voltage (LuV)

Large Plasma Turbine

The Large Plasma Turbine (LPT) is an LuV tier multiblock for generating power from plasma. The LPT is a direct upgrade from the singleblock plasma generators because it outputs up to 4A of power with much higher efficiency. However, a turbine must be placed inside the controller for the machine to run, the input rate of plasma must be carefully regulated, and it must be running for at least 50 seconds to fully warm-up. Turbines come in four different sizes and many different materials each with their own efficiency bonus and optimal flow rate (L/s). Power is extracted from a 4A dynamo hatch on the back of the structure as the plasma condensates into liquid. Breaking the dynamo hatch while the machine is running causes it to explode. Save on fuel by automatically toggling the LPT with an RS latch connected to a Lapotronic Supercapacitor.

The LPT is superseded by the XL Turbo Plasma Turbine in ZPM which consumes as much plasma and produces as much power as 16 LPT, but only requires 12 turbines. It also supports multi-amp and laser energy hatches for serious power generation.

Spreadsheet: GTNH Power Planner 2.9

Construction

The LPT has no tiered components. The maintenance hatch, input hatch, and output hatch may replace any turbine casing on the back half of the structure. The dynamo hatch is limited to the center casing on the very back of the structure and cannot be greater than 4A. There is no muffler hatch so do not include one. Use the Multiblock Structure Hologram Projector to visualize/build the structure.

Unique to large turbines is the turbine housing which is effectively a ULV input bus for storing an extra turbine that automatically replaces the one inside the controller once it breaks. It is completely optional and gated to UV, but helps maximize runtime.

Structure

  • Controller: Front center, 2nd layer
  • 14 Tungstensteel Frame Box
  • 8-14 Tungstensteel Turbine Casing
  • 12 Tungstensteel Pipe Casing
  • 0+ Turbine Housing: Any back turbine casing
  • 1 Dynamo Hatch: Back center turbine casing
  • 1 Maintenance Hatch: Any back turbine casing
  • 1+ Input Hatch: Any back turbine casing
  • 0+ Output Hatch: Any back turbine casing
  • Mandatory Air: 3x3 area in front of controller

Wallsharing

LPTs may wallshare each of their sides to save on space, casings, and hatches. However, do NOT share the input hatch because the fuel is not split evenly between the LPTs--one consumes everything and the other receives nothing. The restriction on the hatch locations make that difficult to accomplish anyway.

Usage

The LPT has two operating modes, listed below, but see the planner linked at the top for the quantifiable differences between them. The former is better in the early to mid game when plasma production is low and the latter is better in the late game when power output is more important than efficiency. Switch modes by using a screwdriver on the controller.

  • Tight Fitting Mode - High efficiency, Low optimal flow rate (power).
  • Loose Fitting Mode - Low efficiency, High optimal flow rate (power).

The speed of the LPT increases linearly up to 100% while active and decreases back to 0% while inactive. Speed is directly proportional to the power output of the machine and takes 50 seconds to reach its maximum value regardless of the turbine size/material. Speed decays extremely fast when the LPT is disabled, the turbine is removed, the structure is broken, or fuel runs out. View the current speed of the turbine by using a Portable Scanner on the controller or looking at the "efficiency" value in WAILA.

Optimal Flow Rate

The rate (L/s) at which plasma enters the LPT is extremely important. Too little plasma and only a fraction of the potential power is generated; too much plasma and a tremendous amount of fuel is wasted. Ideally, plasma enters the LPT at the optimal flow rate of the turbine which changes significantly with size/material and the operating mode of the machine. Although visible in NEI, the optimal flow rate ( m ˙ ∗ {\displaystyle {\displaystyle {\dot {m}}^{*}}} ) in L/s can be calculated with the following equations where k {\displaystyle {\displaystyle k}} is an arbitrary multiplier associated with each material, speed is the Tinker's Construct mining speed of the material, size is a constant between 1=small and 4=huge, and η 0 {\displaystyle {\displaystyle \eta _{0}}} is the base efficiency of the turbine.

m ˙ ∗  (Tight) = k × Speed × Size × 1 , 000 EU/L {\displaystyle {\displaystyle {\dot {m}}^{*}{\text{ (Tight)}}=k\times {\text{Speed}}\times {\text{Size}}\times {\frac {1,000}{\text{EU/L}}}}}

m ˙ ∗  (Loose) = k × Speed × Size × 2 , 000 EU/L × 1.03 20 ( η 0 − 0.8 ) {\displaystyle {\displaystyle {\dot {m}}^{*}{\text{ (Loose)}}=k\times {\text{Speed}}\times {\text{Size}}\times {\frac {2,000}{\text{EU/L}}}\times 1.03^{20(\eta _{0}-0.8)}}}

The quicker and easier way to calculate the optimal flow rate in tight fitting mode is to divide the optimal plasma EU/t (left value in NEI) by the density of the plasma, listed below in the following table, and then multiply the result by 20. Some plasmas have slightly lower densities and thus higher optimal flow rates--especially if the LPT is in loose mode. The player may need to upgrade their fluid regulator or add a second input hatch to meet the increased demand. Eventually it becomes necessary to switch to AE2 fluid P2P tunnels which effectively have no transfer limit and no regard for temperature or heat capacity.

Fuel EU/L Fuel EU/L Fuel EU/L
Carbon Plasma 12,288 Chlorine Plasma 172,032 Rhugnor Plasma 333,824
Hydrogen Plasma 20,480 Force Plasma 180,000 Naquadah Plasma 337,920
Bedrockium Plasma 20,480 Potassium Plasma 183,705 Barium Plasma 342,302
Phosphorus Plasma 30,720 Calcium Plasma 188,416 Lanthanum Plasma 344,801
Deuterium Plasma 40,960 Argon Plasma 188,416 Praseodymium Plasma 346,931
Desh Plasma 50,176 Rhenium Plasma 190,464 Cerium Plasma 346,931
Tritium Plasma 61,440 Titanium Plasma 196,608 Promethium Plasma 347,996
Meteoric Iron Plasma 69,632 Vanadium Plasma 198,451 Neodymium Plasma 347,996
Germanium Plasma 74,752 Chrome Plasma 202,342 Runite Plasma 350,000
Helium Plasma 81,920 Manganese Plasma 202,752 Samarium Plasma 353,280
Advanced Nitinol Plasma 93,184 Dragonblood Plasma 205,824 Europium Plasma 355,635
Chromatic Glass Plasma 93,184 Oriharukon Plasma 205,824 Gadolinium Plasma 366,551
Ardite Plasma 100,352 Iron Plasma 206,438 Terbium Plasma 368,885
Cosmic Neutronium Plasma 100,352 Thallium Plasma 208,896 Holmium Plasma 376,176
Six-Phased Copper Plasma 100,352 Nickel Plasma 213,811 Erbium Plasma 376,217
Infinity Plasma 100,352 Cobalt Plasma 217,497 Thulium Plasma 378,470
Creon Plasma 100,352 Copper Plasma 219,340 Ytterbium Plasma 379,695
Awakened Draconium Plasma 100,352 Zinc Plasma 226,304 Lutetium Plasma 381,296
Draconium Plasma 100,352 Gallium Plasma 229,376 Tantalum Plasma 384,000
Lithium Plasma 100,352 Arsenic Plasma 230,400 Tungsten Plasma 384,778
Ichorium Plasma 100,352 Neptunium Plasma 242,688 Osmium Plasma 393,659
Naquadria Plasma 100,352 Rubidium Plasma 243,712 Iridium Plasma 397,148
Neutronium Plasma 102,400 Strontium Plasma 249,446 Platinum Plasma 399,360
Beryllium Plasma 110,592 Curium Plasma 252,928 Gold Plasma 401,408
Boron Plasma 112,640 Yttrium Plasma 255,180 Mercury Plasma 409,600
Nitrogen Plasma 129,024 Fermium Plasma 263,168 Lead Plasma 423,936
Iodine Plasma 130,048 Niobium Plasma 269,516 Bismuth Plasma 425,984
Tellurium Plasma 130,048 Molybdenum Plasma 272,384 Radon Plasma 450,560
Oxygen Plasma 131,072 Palladium Plasma 282,214 Thorium Plasma 471,040
Fluorine Plasma 147,456 Silver Plasma 282,685 Uranium 235 Plasma 481,280
Sodium Plasma 148,684 Astral Titanium Plasma 284,672 Uranium 238 Plasma 487,424
Tin Plasma 150,000 Cadmium Plasma 293,601 Plutonium 241 Plasma 497,664
Magnesium Plasma 152,371 Flerovium Plasma 295,936 Americium Plasma 501,760
Aluminium Plasma 159,744 Indium Plasma 296,509 Hypogen Plasma 502,784
Raw Silicon Plasma 160,563 Antimony Plasma 309,760 Plutonium 239 Plasma 503,808
Dysprosium Plasma 165,888 Tritanium Plasma 330,752 Celestial Tungsten Plasma 720,000
Sulfur Plasma 170,393 Caesium Plasma 332,513

Power & Overflow

The power generated by the LPT depends on the current flow rate ( m ˙ {\displaystyle {\displaystyle {\dot {m}}}} ), the optimal flow rate ( m ˙ ∗ {\displaystyle {\displaystyle {\dot {m}}^{*}}} ), and the efficiency of the turbine ( η {\displaystyle {\displaystyle \eta }} ). Exceeding the optimal flow rate generates additional power with diminishing returns based on the overflow tier ( T {\displaystyle {\displaystyle {\text{T}}}} ) of the turbine. There are only three overflow tiers in total and depends strictly on the material of the turbine. A higher overflow tier also increases the maximum flow rate ( m ˙ m a x {\displaystyle {\displaystyle {\dot {m}}_{max}}} ). View the overflow of a turbine through NEI and the current power output of the machine through WAILA.

Power is extracted from a 4A dynamo hatch on the back of the structure. Do not break the dynamo hatch while the machine is running or else the LPT will explode. Exceeding the maximum EU/t or the total EU in the dynamo's buffer is perfectly safe; the LPT will not explode if an attached battery buffer or Lapotronic Supercapacitor (LSC) is full and there is nowhere for the EU to go. Any additional EU is simply voided. It is highly recommended to automatically toggle the LPT with a redstone RS latch to avoid wasting fuel--see the LSC page for a guide on setting that up.

Large Plasma Turbine
EU/t = m ˙ × EU/L 20 × η × { 1 − | m ˙ − m ˙ ∗ | m ˙ ∗ , if  m ˙ ≤ m ˙ ∗ 1 − | m ˙ − m ˙ ∗ | m ˙ ∗ × ( 3 T + 1 ) , if  m ˙ > m ˙ ∗ {\displaystyle {\displaystyle {\text{EU/t}}={\dot {m}}\times {\frac {\text{EU/L}}{20}}\times \eta \times {\begin{cases}1-{\frac {|{\dot {m}}-{\dot {m}}^{*}|}{{\dot {m}}^{*}}},&{\text{if }}{\dot {m}}\leq {\dot {m}}^{*}\\1-{\frac {|{\dot {m}}-{\dot {m}}^{*}|}{{\dot {m}}^{*}\times (3{\text{T}}+1)}},&{\text{if }}{\dot {m}}>{\dot {m}}^{*}\end{cases}}}}
m ˙ m a x = ⌊ m ˙ ∗ ⌋ × ( 1.5 T + 1 ) {\displaystyle {\displaystyle {\dot {m}}_{max}=\lfloor {\dot {m}}^{*}\rfloor \times (1.5{\text{T}}+1)}}

Example

The following graph depicts the relationship between the flow rate ( m ˙ {\displaystyle {\displaystyle {\dot {m}}}} ) of Helium Plasma and the power generated by an LPT with a normal Draconium turbine in tight fitting mode. The efficiency of the turbine is 150%, the optimal flow rate is 21 L/s, and the overflow efficiency is Tier 3. This means the maximum flow rate is 21 L/s x 5.5 = 115.5 L/s and the LPT follows the top line in red. The lower overflow efficiency tiers are only visible for comparison purposes. Notice how quickly the EU/t increases as the flow rate approaches the optimal value and then how quickly the turbine loses efficiency afterwards. Loose fitting mode and every other turbine follows a very similar pattern.

Power curve for an LPT with a normal Draconium turbine in tight fitting mode and Helium Plasma for fuel.

Turbines

A turbine must be placed inside the GUI of the controller for the machine to run. Turbines come in four different sizes and many different materials each with their own efficiency bonus and optimal flow rate. There are too many different permutations to list them all here, but the planner linked at the top has all the relevant information and even a calculator for determining the power output and lifespan of any turbine with any fuel.

  • Small turbines are crafted with long magnalium rods (available as early as LV)
  • Normal turbines are crafted with long titanium rods (available at the end of HV after traveling to the moon)
  • Large turbines are crafted with long tungstensteel rods (available in IV after the tungsten processing line)
  • Huge turbines are crafted with long americium rods (available in ZPM after building a Fusion Reactor Mk-II)

Durability

Turbines slowly lose durability proportional to the power generated. The total durability of a turbine depends on the material and instantly voids once it reaches 0%. Turbines cannot be inserted or extracted from the controller, but turbine housings check if the controller is empty once every 60 seconds to insert a new one. Use a screwdriver on the housing to decrease the interval, as necessary, and re-enable the LPT with a machine controller cover.

The following equation calculates the lifespan of a turbine (in hours) from the current power output of an LPT. Turbines generally have lifespans of several hundred hours (or more) so they do not need to be replaced very often.

Lifespan (h) = Durability 36 × Min ( 0.2 × EU / t , ( EU / t ) 0.6 ) {\displaystyle {\displaystyle {\text{Lifespan (h)}}={\frac {\text{Durability}}{36\times {\text{Min}}{\bigl (}0.2\times {\text{EU}}/{\text{t}},({\text{EU}}/{\text{t}})^{0.6}{\bigr )}}}}}

The following are recommended turbines and flow rates based on the maximum EU/t of various 4A dynamo hatches. It is very common to skip a few of these because the cost of replacing healthy turbines may not be worth the slight boost in performance. Note that this list is slightly different from the other large turbines and even the XL Turbo Plasma Turbine because different fuels have different densities and the LPT is very limited by the size of the dynamo hatch. Use the planner linked at the top for a complete list of turbine materials and full setup breakdowns.

Alternatively, send the plasma through an Extreme Heat Exchanger to produce dense supercritical steam and generate at least 50% more power in XL Turbo Steam Turbines. More infrastructure is required, but it saves on Fusion Reactors.

Tier Size Material Efficiency Mode Fuel Flow Rate Power Dynamo Lifespan
LuV Normal Draconium 150% Tight Helium Plasma 21 L/s 129,094 EU/t LuV (4A) 78.1 h
ZPM Huge Draconium 200% Tight Niobium Plasma 13 L/s 350,370 EU/t ZPM (4A) 85.8 h
Large Duranium 215% Tight Niobium Plasma 15 L/s 434,594 EU/t ZPM (4A) 70.7 h
Large Gaia Spirit 225% Tight Niobium Plasma 15 L/s 454,808 EU/t ZPM (4A) 1,427 h
UV Huge Adamantium 230% Tight Niobium Plasma 20 L/s 619,886 EU/t UV (4A) 15.2 h
Huge Ext. Unst. Naquadah 215% Tight Niobium Plasma 47 L/s 1,361,729 EU/t UV (4A) 156.7 h
Huge Trinium 210% Tight Americium Plasma 41 L/s 2,059,608 EU/t UV (4A) 43.7 h
UHV Huge Duranium 184% Loose Americium Plasma 56 L/s 2,585,067 EU/t UHV (4A) 32.3 h
Huge Gaia Spirit 193% Loose Americium Plasma 59 L/s 2,856,770 EU/t UHV (4A) 631.9 h
Huge Adamantium Alloy 180% Tight Americium Plasma 65 L/s 2,935,296 EU/t UHV (4A) 74.9 h
Huge Cosmic Neutronium 250% Tight Americium Plasma 97 L/s 6,083,840 EU/t UHV (4A) 77.4 h
Huge Infinity 300% Tight Celest. Tung. Plasma 59 L/s 6,372,000 EU/t UHV (4A) 1,204 h